Shen ChangHongShen ChangHong

To be a supplier of high quality
laboratory analytical instruments in China.

中文 / English

0086-0755-26450374 / 17748681632@163.com

Technical & Business Support: 8:30-18:00 every day

How to Distinguish Between Turbidity and Colority in Water?

2026-10-29 14:55:19    Editor in charge: 深圳市昌鸿科技有限公司     0

How to Distinguish Between Turbidity and Colority in Water?


In the water quality testing and water treatment industry, turbidity and colority are the two most basic and core sensory indicators. They are also key parameters for the acceptance of tap water, surface water, wastewater, pure water, and circulating water.
 In daily work, many people easily confuse the two, or even mistakenly believe that cloudy water means colored water, and clear water means colorless water. In fact, turbidity and colority are two relatively independent water quality evaluation systems, differing in indicator sources, testing principles, and treatment methods.
 This article provides a clear and easy-to-understand explanation of the core differences between turbidity and colority.


I. What is turbidity? (How to measure the “Clarity” of Water)
1. Definition
Turbidity refers to the degree of cloudiness caused by the scattering,absorption,and blocking of light by suspended solids and colloidal particles.

Silt, suspended solids, algae, microorganisms, residual flocs, and fine impurities can all lead to water cloudiness and recreased transparency, resulting in elevated turbidity.

Simply put: Turbidity = How cloudy the water is.
2. Core Characteristics
• Primary sources: Derived mainly from water-insoluble solid particles and colloidal particles.

• Removal methods: Can be significantly reduced through physical processes such as sedimentation, coagulation, and filtration.

• Filtration impact: Turbidity typically drops significantly after filtration.

• Turbidity vs. Color: Clear water can have high color, while cloudy water can have low color.

• Iron & Manganese behavior: Ferrous iron (Fe2+) and manganous manganese (Mn2+) do not increase turbidity in their dissolved states. They contribute to both turbidity and color only after oxidation converts them into insoluble iron and manganese hydroxide particles.

3. Testing Standards and Units

• Unit: NTU (Nephelometric Turbidity Unit).

• Measurement method: 90° scattered light method, measured with a turbidimeter.

• Standards: According to China's National Drinking Water Standard (GB 5749), the limit is Generally less or equal to 1 NTU. When restricted by raw water sources or treatment technology limitations, the limited is less or equal to 3 NTU.


II. What Is Colority? (Measuring the "Intensity of Water Color) 

1. Definition

Colority refers to the intensity of water color caused by colored substances present in the water. In water quality testing, "true color" is typically measured, which is the color obtained after the water sample is filtered to remove suspended solids. True color mainly originates from dissolved and colloidal colored substances. The color measured directly from an unfiltered water sample is called "apparent color," which is affected by suspended particles and cannot be used as an official basis for judgment.

The color of water bodies primarily originates from humic acids, natural organic matter (NOM), dissolved iron and manganese ions, industrial dyes, and degraded organic compounds.

Simple understanding: Color = Whether the water has a visible color.

2. Core Characteristics

• Primary sources: True color mainly originates from dissolved and colloidal colored substances.

• Removal Methods: Conventional sedimentation and filtration are highly ineffective at removing dissolved pigments. Colloidal colored substances can be partially removed through coagulation and filtration, but coagulation is largely ineffective against low-molecular-weight dissolved pigments.

• Clarity vs. Color: Water can be perfectly clear and turbid-free, yet still exceed the allowable color limits.

• Method limitations: The Platinum-Cobalt (Pt-Co) method is only suitable for yellow-spectrum water bodies (such as surface water and tap water). For industrial wastewater with complex colors, spectrophotometry is generally used to measure apparent color.

3. Testing Standards and Units

• Units: Degrees (Platinum-Cobalt color scale, Hazen) / Pt-Co units.

• Testing Methods: Platinum-Cobalt visual comparison method, Spectrophotometry.

•Standards: According to Chinese National Drinking Water Standard (GB 5749),the Limit is less or equal to 15 degrees, and must be free from any objectionable or unusual color.

 

III. Core Distinction Between Turbidity and Colority (Industry Focus)
Many water quality anomalies stem from confusing turbidity contamination with color contamination:
1. High Turbidity = Highly Particulate (Visible Impurities)
Such as yellow muddy water, suspended solids, and cloudy wastewater, the primarily problem is excessive turbidity.
2. High Color = High Concentration of Colored Substances (Not Necessarily Visible Particles).
Clear yellowish surface water, light-colored wastewater, and tea-like water bodies may have very low turbidity but exceed limits for true color.

Note: Turbidity colloids are not identical to color colloids. Colorless colloids (such as emulsified oil and silica sol) increase turbidity but produce virtually no color. Conversely, humic-type colored colloids contribute to both color and turbidity. While the substances responsible for these two indicators overlap, their evaluation frameworks remain completely independent.
Classic Scenario Comparison

Yellow Muddy Water: High turbidity, high apparent color; true color must be determined after filtration and is not necessarily high.

Diluted Tea: Low turbidity, high true color.

Emulsified Milky Water: High turbidity, low true color.

Compliant Tap Water: Low turbidity, low color.


IV. Differences in Water Treatment Processes (Engineering Applications)

Turbidity Remediation

Can be efficiently removed by using standard physical processes:

Flocculation, sedimentation, sand filtration, precision filtration, and ultrafiltration (UF).

Colority Remediation

Conventional filtration offers limited removal of dissolved true color, though colloidal color can be partially removed via coagulation and filtration. Dissolved color typically requires advanced treatment:

Ozone oxidation, activated carbon adsorption, decolorizing agents, biochemical degradation, and Advanced Oxidation Processes (AOPs).


V. Common Industry Misconceptions

Clear Water ≠ Compliant Water Quality

The human eye cannot detect microscopic colloids or low concentrations of pigments; instrument testing is mandatory.

Compliant Turbidity ≠ Compliant Color

Filtration primarily targets turbidity and has limited effect on dissolved true color. Many water purification projects achieve compliant turbidity levels but fail on color standards.

Apparent Color Is Not Equal to True Colority

Standard testing requires filtration to measure true color. The apparent color of an unfiltered water sample only provides sensory reference value and cannot serve as the basis for true color or color compliance determination.

 

VI. Summary

Turbidity measures particles, representing the cloudiness of the water, and addresses the issue of "cloudiness."

Color measures colored substances, representing the staining of the water, and addresses the issue of "tint."

These two indicators are relatively independent yet equally indispensable. They serve as the most intuitive and critical water quality benchmarks for judging water cleanliness, pollution levels, and the performance of water purification equipment.