Shen ChangHongShen ChangHong

To be a supplier of high quality
laboratory analytical instruments in China.

中文 / English

0086-0755-26450374 / alex.zhao@shenchanghong.com

Technical & Business Support: 8:30-18:00 every day

MULP-8C_Multi-parameter Water Quality Analyzer

MULP-8C

[Product Overview]

The multi-parameter water quality analyzer is capable of measuring a variety of water quality parameters simultaneously. It offers users a comprehensive, efficient, and precise solution for water quality analysis, allowing researchers to obtain data on different parameters from a single instrument for integrated analysis and study. The product can measure a wide range of parameters, including but not limited to chemical parameters, physical parameters and biological parameters. With its comprehensive detection capabilities, efficient operation, and broad application range, the multi-parameter water quality analyzer has become an ideal choice in the modern field of water quality monitoring.

[Application Area]

Product Details
Custom Matching



MULP-8c multi-parameter Water Quality Analyzer.


1. Equipped with DIS-16B (or optional DIS-20B / 25B / 36B) digestion instrument;


2. With printing and USB data upload function;


3. 5-inch large-screen color touch screen, both Chinese and English display;


4. With one-click recovery function;


5. The wavelength is automatically selected.




Working Principle



The multi-parameter water quality measuring instrument uses a single wavelength of light to pass through the sample to be tested, and according to Lambert-Beer's law, the concentration value of a substance contained in the sample is calculated by measuring the absorbance value.



Technical Parameter

Measurement parameters

80 items including COD, ammonia nitrogen, total phosphorus, total nitrogen, copper, iron, nickel, hexavalent chromium and nitrite (see table below)

Wavelength

340nm, 420nm, 440nm, 470nm, 520nm, 540nm, 560nm, 610nm, 630nm, 660nm, 680nm, 700nm (Any wavelength within the above range can be customized)

Indication error

≤±5 %

Repeatability

≤±3%

Optical stability

Absorbance drift ≤0 .002A/20min

Curve and Storage

200 factory calibration curves, 3500 user-defined curves; Can store 100,000 records.

Display

 5 inch 800*480 color touchscreen

Printer

Built-in thermal printer

Dimension

400mm×320mm×182mm

Power

30W

Weight

4.75 kg

Data interface

USB

Working environment

(1) Ambient temperature: 5~40℃ ⑵ Relative humidity: ≤85% ⑶ Power supply: AC 220 (165V-240V) (4) No significant vibration and electromagnetic interference, avoid direct sunlight.

 


Features




1. It can measure the concentration, absorbance and transmittance of nearly 100 parameters in water quality, results can be saved, printed, queried or uploaded to computer.2. The measurement wavelength can be selected.

3. The multi parameter water quality analyzer can take backup measures for the curve and data record calibrated by users, and can resume operation in case of accidental loss.

4. The instrument is equipped with various safety measures, both powering on and system set all need password. 

5. The instrument has its own calibration function, which can effectively eliminate the drift error caused by long-term use.

6. The instrument adopts 5-inch large screen color touch screen operation, easy to operate.

7. The light intensity is divided into 16 levels and can be set arbitrarily, which can effectively solve the problem of measuring range expansion caused by signal strength.



8. Except the ex-factory curves, users can add, calibrate, and save curves in the instrument by themselves.

9. The curve can be inquired. Except the curve equation, the standard value of each standard substance, the corresponding absorbance, the calibration time and the number of the calibration personnel all can be inquired, so as to completely reproduce the state of calibration.

10. Type C can store 300 curves, 1000 records, and type D can store 3500 curves, 100000 records.

10. The optical system is optimized and upgraded (type D). The system is more stable, with better accuracy and stability.



11. When querying records, you can print a single or a whole page results.

12. The system has bilingual function and can switch between Chinese and English.





13.You can choose straight line method or broken line method for the instrument measurement. Choosing the broken line method can measure some parameters with poor linearity more accurately.

14. With one key recovery function, it can realize one key recovery when the factory curve and users' curve data records are lost due to accidents.



Measurement Parameters and Accuracy

 No.

Measurement item

Measuring range

Unit

Indication error

1

CODCr

5-200 or 5-150

mg/L

5%

2

CODCr

200-2000 or 150-2000

mg/L

5%

3

Ammonia nitrogen(Low range)

0.00-5.00

mg/L

3%(F.S)

4

Ammonia nitrogen(High range)

5.00-25.00

mg/L

3%(F.S)

5

Total phosphorus(Low range)

0.00-2.00

mg/L

5%(F.S)

6

Total phosphorus(High range)

2.00-10.00

mg/L

5%(F.S)

7

Total nitrogen(Low range)

0.00-10.00

mg/L

5%(F.S)

8

Total nitrogen(High range)

10.0-100.0

mg/L

5%(F.S)

9

CODMn(Permanganate index)

0.00-10.00

mg/L

0.2或5%

10

Residual chlorine(Low range)

0.00-2.00

mg/L

0.1或5%

11

Residual chlorine(High range)

2.0-10.0

mg/L

5%

12

Total chlorine(Low range)

0.00-2.00

mg/L

0.1或5%

13

Total chlorine(High range)

2.0-10.0

mg/L

5%

14

Chlorine dioxide(Low range)

0.00-2.00

mg/L

0.2或5%

15

Chlorine dioxide(High range)

2.0-20.0

mg/L

5%

16

Sulfate

0-200

mg/L

5%(F.S)

17

Nitrate(Nitrogen)

0.00-10.00

mg/L

0.1或5%

18

Phosphate(Low range)

0.00-10.0

mg/L

0.2或5%

19

Phosphate(High range)

10.0-50.0

mg/L

5%

20

Nitrite nitrogen(Low range)

0.00-1.00

mg/L

0.05或5%

21

Nitrite nitrogen(High range)

1.0-5.0

mg/L

5%

22

Sulfide

0.00-1.00

mg/L

5%(F.S)

23

Fluoride

0.00-10.0

mg/L

 5%(F.S)

24

Cyanide

0.00-0.50

mg/L

5%(F.S)

25

Bromide

0.00-5.00

mg/L

5%(F.S)

26

Formaldehyde

0.00-2.50

mg/L

5%(F.S)

27

Volatile phenol(Low range)

0.00-5.00

mg/L

5%(F.S)

28

Volatile phenol(High range)

5.0-10.0

mg/L

5%(F.S)

29

Hydrazine

0.00-0.50

mg/L

5%(F.S)

30

Aniline compound(Low range)

0.00-1.00

mg/L

5%(F.S)

31

Aniline compound(High range)

1.0-5.0

mg/L

5%(F.S)

32

Silica

0.00-5.00

mg/L

5%(F.S)

33

Silicate

0.00-6.00

mg/L

5%(F.S)

34

Total alkalinity(Low range)

0-100

mg/L

5%(F.S)

35

Total alkalinity(High range)

100-1000

mg/L

5%(F.S)

36

Total hardness

0.00-500

mg/L

5%(F.S)

37

Chloride ion(Chloride)

0.00-100.0

mg/L

5%(F.S)

38

Ozone

0.00-2.50

mg/L

5%(F.S)

39

Anionic surfactant

0.00-1.00

mg/L

5%(F.S)

40

Ammonium ion (Low range)

0.00-2.50

mg/L

5%(F.S)

41

Ammonium ion (High range)

2.5-25.0

mg/L

5%(F.S)

42

Available chlorine

0.0-200

mg/L

5%(F.S)

43

Chlorite

0.00-20.0

mg/L

5%(F.S)

44

Cyanuric acid

0-200

mg/L

5%(F.S)

45

Urea

0.00-4.00

mg/L

5%(F.S)

46

Copper(Low range)

0.00-1.00

mg/L

5%(F.S)

47

Copper(High range)

1.0-10.0

mg/L

5%(F.S)

48

Zinc

0.00-5.00

mg/L

5%(F.S)

49

Trace Nickel(Low range)

0.000-0.500

mg/L

5%(F.S)

50

Trace Nickel(High range)

0.50-1.00

mg/L

5%(F.S)

51

Nickel

0.00-10.00

mg/L

5%(F.S)

52

Iron(Low range)

0.00-5.00

mg/L

5%(F.S)

53

Iron(High range)

5.0-10.0

mg/L

5%(F.S)

54

Ferrous(Low range)

0.00-5.00

mg/L

5%(F.S)

55

Ferrous(High range)

5.0-10.0

mg/L

5%(F.S)

56

Hexavalent chromium

0.00-1.00

mg/L

5%(F.S)

57

Cadmium

0.05-0.50

mg/L

5%(F.S)

58

Manganese(Low range)

0.01-0.10

mg/L

5%(F.S)

59

Manganese(High range)

0.10-1.00

mg/L

5%(F.S)

60

Manganese

0.00-5.00

mg/L

5%(F.S)

61

Total chromium

0.00-1.00

mg/L

5%(F.S)

62

Aluminum(Low range)

0.00-0.50

mg/L

5%(F.S)

63

Aluminum(High range)

0.5-5.0

mg/L

5%(F.S)

64

Silver

0.00-1.00

mg/L

5%(F.S)

65

Molybdenum

0.00-1.00

mg/L

5%(F.S)

66

Arsenic(Low range)

0.000-0.500

mg/L

5%(F.S)

67

Arsenic(High range)

0.50-5.00

mg/L

5%(F.S)

68

Beryllium

0.00-0.10

mg/L

5%(F.S)

69

Boron

0.00-2.00

mg/L

5%(F.S)

70

Mercury

0.000-0.500

mg/L

5%(F.S)

71

Lead

0.00-0.50

mg/L

5%(F.S)

72

Antimony

0.00-10.00

mg/L

5%(F.S)

73

Barium

0-100

mg/L

5%(F.S)

74

Color(Low range)

0-50.0

PCU

3%(F.S)

75

Color(High range)

50-500

PCU

3%(F.S)

76

Turbidity(Low range)

0-400

NTU

≤2%(F.S)

77

Turbidity(High range)

0-1000

NTU

≤2%(F.S)

78

Suspended solids

0-1000

mg/L

≤2%(F.S)

79

PH(Colorimetric method)

5.00-8.00

pH

0.1±0.1pH

80

Dissolved oxygen(Colorimetric method)

0.0-10.0

mg/L

0.1±5%

 


Online Service