Shen ChangHong
To be a supplier of high quality
laboratory analytical instruments in China.
The total nitrogen micro reflux test method developed by Shenzhen Changhong science and Technology Co., Ltd. (hereinafter referred to as shenchanghong) is simple, fast and economical in operation, and the test results are accurate and reliable. Shenchanghong can provide a complete analysis scheme of total nitrogen micro reflux test method, and users do not need to prepare their own total nitrogen reagents. The scheme includes total nitrogen analyzer, ds-16b / 20B / 25B / 36B digester and matching total nitrogen reagent. The total nitrogen reagent is used in combination with digester and total nitrogen analyzer. The analytical procedure is simple and convenient, which meets the requirements of national industry standards.
Shenchanghong's Zinc tester (chzn-180 / pchzn-180 / mulp-8a / C / D / pmulp-4c / 8C / mulp-4b / gw-2000 / chmm-900, etc.) selects the corresponding zinc test program in the main menu. It does not need to re-establish the standard curve, just put the zinc reagent test tube in the instrument to read the zinc value expressed in concentration units, and save the record results.
Shenchanghong's copper tester (chcu-100 / pchcu-100 / mulp-8a / C / D / pmulp-4c / 8C / mulp-4b / gw-2000 / chmm-900, etc.) selects the corresponding copper test program in the main menu, does not need to re-establish the standard curve, only needs to put the copper reagent test tube into the instrument to read the copper value expressed in concentration units, and can save the record results.
Shenchanghong's aluminum tester (chal-130 / pchal-130 / mulp-8a / C / D / pmulp-4c / 8C / mulp -, etc.) selects the corresponding aluminum test program in the main menu. Without re establishing the standard curve, it is only necessary to put the aluminum reagent test tube into the instrument to read out the aluminum value expressed in concentration units and save the record results.
Shenchanghong's Cadmium tester (chcd-170 / P chcd-170 / mulp-8a / C / D / pmulp-4c / 8C / mulp-4b / gw-2000 / chmm-900, etc.) selects the corresponding cadmium test program in the main menu, does not need to re-establish the standard curve, only needs to put the cadmium reagent test tube into the instrument to read out the cadmium value expressed in concentration single bit, and can save the record results.
The operation steps and precautions of COD analyzer are the knowledge that many friends want to know before using. With the progress of the times, COD measuring instrument is also slowly emerging. COD measuring instrument is a kind of chemical oxygen demand measuring instrument, which can quickly calculate oxygen demand. Here is how to use and operate it