Product Details
Custom Matching
Technical Specifications
Measuring range | Total Nitrogen:0.00~10.00 ; 10.0~100.0mg/L(dilute if excess the measuring range) |
Measuring accuracy | 0.01 mg/L ; 0.1 mg/L |
Indication error | ≤±5 % |
Repeatability | ≤±2% |
Optical stability | Absorbance drift ≤0 .002A/20min; Light source lifespan 100,000 hours |
Testing standard | HJ_636-2012 /BS ISO 23696-2:2023 |
Analytical method | Alkaline potassium persulfate digestion UV spectrophotometry /Chromotropic acid spectrophotometry (Colorimetric tubes) |
Processing capacity | 16 samples per run |
Temperature control system | Total nitrogen digestion temperature: 125℃;Temperature range: room temperature ~200℃; Temperature Accuracy:±0.5℃;Time period:1~9999min |
Digestion period | 30min |
Curve and Storage | 200 factory calibration curves, 3500 user-defined curves; Can store 100,000 records. |
Display | Instrument: 5 inch 800*480 color touchscreen; Digester: 3.5 inch 480*320 color touchscreen |
Printer | Built-in thermal printer |
Power | Instrument: 30W Digester: 300W |
Dimensions | Instrument:400mm×320mm×182mm;Digester :249mm×350mm×199mm |
Weight | Instrument:4.75kg Digester:5.6kg |
Data interface | USB |
Working environment | (1) Ambient temperature: 5~40℃ ⑵ Relative humidity: ≤85% ⑶ Power supply: AC 220 (165V-240V) (4) No significant vibration and electromagnetic interference, avoid direct sunlight. |
Functional Features
The measurement instrument and digestion device are separate, ensuring the stability of the optical system.
The analyzer features a cold light source and a narrow-band interference optical system, providing excellent optical stability. The light intensity is adjustable across 16 levels, allowing for customizable settings that effectively address measurement range extension due to signal strength variations.
The instrument features a color touch screen with a user-friendly interface, displaying in both Chinese and English.
The analyzer supports curve queries; in addition to retrieving the curve equation, users can access the standard values and corresponding absorbance for each calibration standard, along with calibration timestamps and operator IDs, fully replicating the calibration conditions.
The digestion device features multi-point error-free calibration, achieving zero-error measurements at set points and completely eliminating errors commonly associated with non-linear temperature sensors in other digestion devices on the market.
Digester includes a timed reminder and an automatic shut-off function after digestion. The instrument is equipped with a secondary protection feature: if the digestion device temperature exceeds 200 degrees Celsius, the power supply will be automatically cut off to ensure safe operation during the digestion process.
In addition to the 250 factory-set calibration curves, users can add and store up to 3,500 custom curves within the instrument.
Storage capacity reaches 100,000 records, including parameter names, concentrations, units, detection times, and operator IDs.
The analyzer also features a printing function, allowing immediate printing of test records or retrieval of previously printed records.
A USB interface enables connection to a computer for easy data transfer.
Packing List
Main Unit: 1 piece
Digester: 1 piece
Colorimetric tube: 5 tubes (16*110mm)
Tube rack: 1 piece
Reagent: 1 kit
USB cable: 1 piece
Power Cord: 2 pieces
Manual: 1 copy
Certificate of Conformity: 1 copy
Warranty Card: 1 copy